Testing and choosing the right model gas detector

02 March 2007
Sarah Ursulan
Add a comment


Worker safety and a facility's security can depend on choosing the right portable gas detector. There are several factors to consider before deciding which detector fits your needs. Assessing and testing gas detectors before you commit yourself will help you choose the right model for the job, explains Sarah Ursulan.

Worker safety and a facility's security can depend on choosing the right portable gas detector. There are several factors to consider before deciding which detector fits your needs.

The first thing you need to do is determine which atmospheric hazards are, or could be, present. Consider the existence of combustibles, toxic gases and volatile organic compounds (VOCs), and the possibility for oxygen enrichment or deficiency. Once you have identified the atmospheric hazards, you can then decide whether you need a single or a multi-gas detector.

It is important to make sure the instrument you choose for an application can support the number and type of sensors you will need. Most confined-space instruments include an oxygen sensor, a catalytic flammable/combustible gas sensor, and one or two electrochemical sensors for detecting specific toxic gases. Some instruments also incorporate an infrared sensor for carbon dioxide or methane.

For the record

You might require a record-keeping feature in the detector, and event logging and data logging come as standard with certain instruments. Data logging instruments are usually set up to keep monitoring information whenever they are switched on, and this information can be crucial for compliance and record keeping. Data logging instruments are also useful in the event of an accident or unusual occurrence, as they provide a snapshot of the conditions at the time of the event. Documentation of proper use could significantly reduce your liability if things go wrong.

Calibration and bump testing (also known as challenge or function testing, to check the detector is working properly) should be straightforward. Most data logging instruments automatically update and store dates and other calibration information. Many manufacturers now offer automatic calibration or docking stations that calibrate, recharge and store calibration records. It is worth enquiring about the availability and cost of calibration and docking stations before you buy the equipment.

One-button operation is useful, especially when the user is wearing gloves. Other specifications include operating temperature and humidity range. Size and weight will also be factors; two detectors might measure the same gases, but one may offer more features while the other may be smaller and lighter.

Portable instruments may use disposable alkaline batteries, rechargeable batteries or both. If the battery is a proprietary design (that is, not a standard shape) check the availability and cost of replacements. If the instrument takes a rechargeable battery, does the price include a battery charger?

There are basic disposable "plug-and-play" models that do not require any sensor or battery replacement, and arrive fully calibrated.

Accessorising

The availability of accessories can make using a detector easier in certain situations, and it's worth checking if these accessories are included. Check the availability of sample draw kits and motorised pumps if your users will be sampling from remote locations. Other useful accessories include hard-hat clips, carry cases, training videos and calibration materials.

Portable gas detectors need to be durable. Check the certifications and standards of the device you are considering before you buy. Ingress protection, or the IP66/67 rating on a product, can identify that an instrument has been tested and is dust-tight and water-resistant (to both water jets and immersion). This test certification further demonstrates the detector's ability to perform reliably in harsh industrial environments.

The ATEX Directive embodies the European requirements for equipment used in potentially explosive atmospheres, while CE marking is the manufacturer's declaration of compliance with all applicable directives. For most products sold in the EU, CE marking and a Declaration of Conformity are mandatory.

Whatever criteria you use in choosing your portable gas detector, you should always try out the instrument in the field. There is no substitute for seeing how an instrument will perform under actual use conditions.

Most leading manufacturers, or their distributors, have evaluation instruments available to try. Sometimes you can rent instruments before you buy them. Choosing a portable gas detector is a safety-critical decision. Assessing  the specifications and versatility of the detector, and checking the equipment's approvals and certification, will help determine which instrument best fits your needs.

Sarah Ursulan is marketing manager at BW technologies, suppliers of gas detection equipment, www.gasmonitors.com


Categories:
Article, Work equipment
Bookmark this article with:

  • Delicious
  • Digg
  • StumbleUpon
  • Propeller
  • Reddit
  • Facebook
  • Google
  • Yahoo
  • Technorati
 
  • Log in to view and post comments
  • Printer-friendly version


Five steps debate

Duncan Spencer's recent article in HSW questioning the utility of the HSE's five steps to risk assessment method has prompted a discussion between Spencer and consultant John Anderson.

Read the debate and add your comments >>

Latest comments


Fines: profit over insurance

A day with the HSE

Should there be a register for consultants?

Isn't this what COSHH legislation is in place for?

One-in-three back pain sufferers blames work

Lord Young's safety review

Latest in the blog


Busman's holiday >>

The not-so-perfect CV >>

How to divine the significant from the
trivial >>

Britain v Germany...again >>

Do not touch! >>

Mastering the art of relaxation >>

Forthcoming events


15-16 September: Health and Safety '10 – Scotland

22 September: FLTA Safety Conference


13-14 October: Health and Safety ’10 – North

4 November: HSW/IIRSM conference 2010

See all >>

Ask a recruitment expert


I'm currently working in the UK. How do I go about securing work in the Middle East?

This is a common question, though the answer today is very different to the answer 18 months or two years ago... read more

My employer is prepared to support my professional development. I’m already CMIOSH and MIIRSM, what should I do next?

Firstly, congratulations. The fact your current company is prepared to support you beyond... read more

I've been made redundant. What else can I do to find a job?

Unfortunately, as you'll no doubt appreciate, there are lots of people in your position at the moment. There are fewer... read more

Click here for tips on how to write a
winning CV >>

Links


1st Degree-level course directory

Industry case studies

Products and services

Find your next job here

HSW on Facebook

HSW on Twitter

Lawyerlocator.com
Search For A Lawyer by town:

Powered by Lawyer Locator
Ask a question or post an answer >>


Follow healthandsafety on Twitter
Follow HSW on Facebook
  • Read current issue
  • Contact us
  • Subscribe
What do you think?










Health
Asbestos
Chemicals (and COSHH)
Disability Discrimination Act
Ergonomics
Musculoskeletal disorders
Noise
Sickness absence
Stress/bullying
Vibration
Asthma
Display Screen Equipment (DSE)
Drugs and alcohol
Risk assessment
Legionnaire's disease
Accident reduction
Enforcement (prosecutions)
Mental health
New and expectant mothers
Older workers
Safe systems of work
Smoking
Safety
Directors' duties
Fire
HSE
Manual handling
Noise
Personal protective equipment (PPE)
Risk assessment
Road safety
Work at height
Electrical safety
Lifting operations
Safe systems of work
Chemicals (and COSHH)
Corporate manslaughter
Migrant workers
Regulation
Asbestos
Confined spaces
Accident reduction
Worker involvement / representation
Violence at work
Workplace transport
Slips, trips, and falls
Work equipment
New and expectant mothers
Training
Insurance
Emergency planning
Lone workers
Enforcement (prosecutions)
First aid
Drugs and alcohol
Accident reporting / RIDDOR
Young workers
Professional Skills
Ask the recruitment expert
Management skills
Qualifications
Training
Training guides
Industry
Catering and leisure
Chemicals
Construction
Public services
Retail and distribution
Transport
Utilities
Financial / general services
Manufacturing / engineering

Halsbury House, 35 Chancery Lane, London WC2A 1EL
Customer Services 0845 370 1234

  • Terms and Conditions
  • Privacy Policy
  • Advertise with us
  • Reprint and Syndication
  • © Lexis Nexis. All Rights Reserved.

  • Partner sites:   LexisNexis
  • Magazines and Journals
  • Conferences and Training
  • Supplier Directory
  • Taxation Jobs
  • Taxation
  • Criminal Law & Justice
  • Legal Jobs
  • Company Law Forum
  • Health and Safety
  • Health and Safety Jobs
  • Environment in Business
  • Green & Environment Jobs
  • Payrolls & Pension Jobs
  • Employment Law Forum
  • www.newlaw-directories.co.uk